Nov 2026
Open-Data Carbon Footprint of Gas, Wind and Solar Power in Italy, with a Stress-Test of ML Surrogates

Problem
How much CO₂ does a kilowatt-hour cost in Italy, depending on whether it comes from a gas plant, a wind farm or a solar park? How certain are those numbers, and which inputs drive them? LCA studies usually answer with a single value per technology, or with uncertainty ranges computed for each technology on its own. But wind and PV share the same background data (steel, aluminium, glass and so on). If you sample those separately, the comparison between technologies looks more uncertain than it really is.
Approach
- Goal and scope: ISO 14040/44 structure, climate change only (GWP100, IPCC AR6), functional unit 1 kWh delivered to the Italian grid. Systems: natural-gas combined cycle (CCGT), onshore wind and ground-mounted crystalline-silicon PV.
- Open data only: IEA PVPS inventories, three public Vestas LCAs, Eurostat, Ember, PVGIS (527 sites over Italy), ISPRA, worldsteel and industry association factors. Every one of the 46 parameters has a distribution and a source, and every download is logged with URL, date, SHA-256 hash and licence.
- Models: one small parametric equation per system, built in Brightway for the baseline and contribution analysis and as a vectorised NumPy twin for the Monte Carlo runs. The two agree to machine precision.
- Joint uncertainty: 10,000 Monte Carlo runs in which shared background factors are drawn once per run for all three systems, followed by Sobol indices for each system and for the PV − wind difference. The estimator was validated on the Ishigami function.
- Machine learning: surrogate models (including polynomial chaos) and their explanations (SHAP, permutation importance), graded against the exact Sobol and Shapley answers that the model itself provides.
The pipeline. Every step is a script, and every number in the manuscript is generated from the result tables.
Results
| System | This study (median, 95 % interval) | IPCC AR5 median (range) |
|---|---|---|
| Natural-gas CCGT | 473 (435–516) g/kWh | 490 (410–650) |
| Utility-scale PV | 25 (18–38) g/kWh | 48 (18–180) |
| Onshore wind | 15 (10–21) g/kWh | 11 (7–56) |
Gas emissions come from its fuel. Wind and PV emissions come mostly from steel, plus the Chinese grid electricity used to make the PV modules.
- Wind emits less than PV in 99.5 % of runs. This depends on a dated, heavy PV mounting-structure inventory: with a structure four times lighter, the share drops to 82 %.
- A shared uncertainty can dominate each system but cancel in the comparison. The steel emission factor has a total-order Sobol index of 0.41 for wind and 0.19 for PV, but only 0.03 for their difference. A first-order sharing factor R = (a − b)²/(a² + b²) predicts this (R = 0.001 for steel; Spearman ρ = 0.92 against the exact shares).
The steel factor drives 41 % of the variance for wind and 19 % for PV, but only 3 % of the gap between them, because it moves both together.
The sharing factor predicts which shared inputs cancel. Sampling them independently overstates the uncertainty of the PV − wind difference.
- ML explanations find the right drivers but get their weight wrong by up to 0.16 in variance share. With correlated inputs, SHAP variance shares stay closest to the exact Shapley effects. Sobol indices that ignore the dependence and permutation importance get worse.
Importance from SHAP and permutation importance (dots) against the exact variance-based answer (grey bars).
Limitations
The PV inventories describe 2018–2020 technology, and the only open ground-mount inventory is a heavy, dated structure. Several background factors are single values from industry associations, with an assumed ±20 % spread. The wind uplift is calibrated on one manufacturer’s LCAs. No ISO critical review was performed.